Temperature Control Change-Out - GDM
TempControl1 TempControl2
Note: If it becomes necessary to remove the housing
be sure to tape off any interior panel at risk
of being scratched.
REQUIRED TOOLS: Permagum, Phillips Head Screwdriver, Hex Head Driver
  • STEP 1: Insert the control bulb into the copper sleeve. Before insertion, be sure there are no kinks in line.

  • STEP 2: IMPORTANT!
    Seal the end of the sleeve with permagum to keep moisture out. (figure 3)

  • STEP 3: Connect the two wires to the new temperature control.

  • STEP 4: Fasten the control onto the mounting plate with two screws. (Item A)

  • STEP 5: Fasten the mounting plate wo the cooler with two screws. (Item B)
  • STEP 6: Replace black control knob and turn the control to the #5 setting.

  • STEP 7: Plug the Cooler in.

    TempControl3
CAUTION
Wait at least 12 hours before re-adjusting control.
This allows for the Cooler to stabalize cycle.