Fluorescent Light Ballast Diagnosis
1. (800501) R2S40-TP input voltage black to white 118 volts. Filament voltage
red to red, blue to blue, yellow to yellow 3.3 to 4.0 volts. High voltage red to blue, blue to yellow 310 volts.
2. (800506) R-140-TP input voltage black to white 118 volts. Filament voltage
red to red, blue to blue, 3.5 to 4.5 volts. High voltage red to blue 180 volts.
3. (800511) RC2S102-TP input voltage black to white 118 volts. Filament voltage
red to red, blue to blue, yellow to yellow, 3.4 to 4.5 volts. High voltage blue to red, blue to yellow 310 volts.
4. (800524) R-1P32-TP input voltage black to white 118 volts. Filament voltage
red to red, blue to blue, 4.0 to 5.0 volts. High voltage red to blue 205 volts.
5. (800540) R2P32-TP input voltage black to white 118 volts. Filament voltage
red to red, blue to blue, 3.5 to 4.5 volts. High voltage red to blue 300 volts.
6. (800559) REL-2P32-SC input voltage black to white 118 volts high voltage
red to blue 610 volts no filament voltage. |
|